首页 产品中心 柴油车烟度计

PRODUCTS CENTER
柴油车烟度计
HPC602不透光烟度计


主要功能特点:

分体式结构设计,操作更方便,数据更精确;
采用分流式取样技术、柴油机加速、减速和稳速时均可测量烟度;
数据自动线性化处理,可显示不透光度N、光吸收系数K和对应滤纸式烟度值SF;
高亮度数码显示;
采用“空气幕”技术保护光学系统免受污染;
检测室自动恒温控制,可防冷凝而影响测试精度;
附自动时间显示;可选配转速测量和油温测量;
出现故障自动诊断显示所在单元;
配内置打印机或蓝牙、RS232、模拟接口;
符合ISO11614和GB3847-2018技术要求。

主要技术参数:

测量范围       不透光度N:  0~99.9%(相当烟度值0~10FSN)
光吸收系数K:0-16.06m-1
转速:0-9990rpm     油温: 0-150℃
示值误差       ≤±2%(测量值)
稳 定 性        自动校零,量矩漂移≤±1%/4h
重 复 性        重复误差≤±1%
分 辨 率        N为0.1%, K为0.01m-1 ,转速为10rpm,油温为0.1℃
输出方式       数字直读显示,可附打印机打印烟浓度(暗度)最大值,测试
时间、日期等。可附接口与计算机联网
测量室温度    70℃(自动恒温),当温度误差≥±10%时,温度及错误指示灯亮
环境条件        温度-5~50℃,相对湿度≤90%
电      源        AC100-240V 50/60Hz 消耗功率150VA
外形尺寸        控制单元 240mm(长)×310mm(宽)×170mm(高)
(含支架)     测量单元 130mm(长)×400mm(宽)×390mm(高)
重      量         控制单元  4k
测量单元  5kg

Main Features:

◆Separated structural design, operation more convenient and more accurate data.
◆Adopted a triage-type sampling technique, diesel engine acceleration, deceleration, and steady speed can be measured when the smoke;
◆Linear automatic data processing, can be displayed opacity degrees N, light absorption coefficient K and the corresponding value of filter paper-type smoke SF;
◆High-brightness digital display;
◆Use of "air curtain" technology to protect the optical system from contamination;
◆Automatic detection of room temperature control, anti-condensation can affect the test accuracy;
◆Automatically attached to the time display; optional speed measurement and oil temperature measurement
◆Show where the failure of automatic diagnosis unit;
◆Equipped with built-in printer (or Bluetooth / RS232 interface);
◆In line with ISO11614 and GB3847-2005 technical requirements.

Main technical parameters:

Test ScopeNo light transmission N:0100% (equivalent to smoke value 0~10FSN)

Light absorption coefficient K:016.06 m-1

RPM09990rpm OIL TEMP: 0150℃

Indication error: ≤±2% ( measured value)

Stability:moment drift≤±1%/4H

Repeatability ≤±1%

Resolution: N:0.1%, K:0.01m-1 ,RPM:10rpm, OIL TEMP:0.1℃

Output mode:digital direct reading, can be attached to the printer to print the smoke concentration ( darkness) maximum value, test time, date. Can interface with computer networking

The measurement chamber temperature:

70 ℃ (automatic), when the temperature error of ± 10%, temperature and error indicator light

And-use temperature: -5~50°C, Relative humidity: 90%

Power: AC100~240V 50/60Hz or DC12V, Power consumption: 150VA

Dimensions: control unit: 240(L)×310(W)×170 (H)mm

( including bracket) measuring unit: 130(L)×400(W)×390(H)mm

Control unit: 4kg

Measuring unit: 5kg